Radiation exposure of auxiliary persons during high dose X-ray examinations of horses
Strahlenexposition der Hilfspersonen bei dosisintensiven Standardradiographien am Pferd
Busse C, Lüpke M, Stadler P, Geburek F, Seifert H
DOI: 10.21836/PEM20080314
Year: 2008
Volume: 24
Issue: 3
Pages: 428-432
interest in the amount of radiation dose of people are exposed to during X-ray examinations of pets. Measurements were carried out during daily routine X-ray examinations in the Clinic for Horses (University of Veterinary Medicine, Hannover). For each high dose X-ray examination seven points on the human body were measured with thermoluminescence dosimeters TLD-100H on the cassette holders. The radiation exposure during high dose x-ray examinations was compared. Knee, pelvis and cervix X-ray examinations were included. During standard X-ray examinations with settings over 16 mAs and at least 80 kV the medial equivalent doses measured on the unprotected eye lens and upper arm ranged between 15 and 50 μSv per X-ray examination. By complying with the regulations on radiation protection and the given code of behaviour the radiation exposure is kept to a minimum and the presence of auxiliary persons during radiographic examinations of the cervix and the hip is tolerable. In isolated cases the attainment of knowledge by means of X-rays always has to justify the radiation hazard of those present (ALARA-principle).